Airwatergreen dehumidifiers maintain a stable humidity level over time. Reducing any humidity energy efficiently and with the same efficiency down to low relative humidity levels. This is important when avoiding condensation on cold surfaces in warm buildings.
The dehumidifiers are easy to install as they do not require any unnecessary ventilation pipes. Dry air and water is produced at the machine.
They are prepare for easy monitoring via Wifi or Modbus connection.
PRESERVING INFRASTRUCTURE FOR DRINKING WATER PRODUCTION & DISTRIBUTION
Airwatergreen dehumidification technology needs half the energy as compared to traditional technology. It is also equally energy efficient at low temperatures. This makes it possible to lower unnecessary heating and instead establish a good climate by removing the moisture from the air.
WATER TREATMENT PLANTS
Challenge
High levels of humidity and high demands on cleanliness. Cold surfaces and pipes with a risk for condensation.
Our solution
Energy efficient dehumidification that continuously control the dehumidification to the right level. Advisable to use dew point sensors to optimise the dehumidification process.
PIPE GALLERIES
Challenge
Cold pipes where condensation is easily formed.
Our solution
Control the dehumidification against the temperature of the surface of the cold pipes to reach the low moisture level needed to avoid condensation.
OPEN WATER BEDS IN FILTER HALLS
Challenge: Large open water surfaces that emit moisture. It is important to always keep the right temperature difference between the water surface and the air in the room.
Our solution: Control the dehumidification to maintain a suitable relative humidity (RH) level independent of the temperature.
Challenge: A correct and stable moisture level is required for the chemicals.
Our solution: Set the relative level required for a correct storage of the chemicals. With a dehumidification capacity needed depending on the humidity load in the storage room.
STAFF AND OTHER AREAS
Challenge: Important with good ventilation. A ventilation that in itself can constitute a humidity load during the part of the year when when the humidity in the air outdoors go up.
Our solution: Adjust the dehumidification capacity after an assessment where the humidity load is estimated. Allow the dehumidifier to maintain the correct humidity level over time using built-in and/or external sensors.
PRODUCT CHOICE
Product selection depends on the moisture load in the room / space. The moisture load can be measured and estimated.
In smaller to medium-sized spaces, FLEX is the natural choice. Dew point sensors can be used to control the FLEX against the correct moisture level to avoid condensation on cold surfaces. FLEX Can be mounted on wall bracket or stand freely on the floor.
REX is advantageously used in larger spaces such as Open water beds and Polymer rooms.
Both FLEX and REX can be connected to existing monitoring systems via Modbus.